CI-PC182 Flue Oxygen Analyzer
It has the characteristics of intelligence, good stability, high reliability, long calibration cycle, etc.;
Wide range of use: the probe can be used safely in the temperature range of 0~500°C;
In-line probe: the probe works in the environment under test, reflecting the oxygen content is real and reliable, fast response speed, low failure rate;
Weatherproof structure design:the structure design of theanalyzer is all metal shell, and anti-corrosion treatment, the visible window is toughened glass, all the detection parts and electrical modules are in the metal exclosure, and excellent sealing.
Principle: Variable Frequency Ion Flow
Measuring range: 0~25.00% O2
Model:
CI-PC182 (All-In-One Tape Display)
CI-PC182-1 (Split-Tape Secondary Instrument)
CI-PC182-2 (Explosion-Proof Split Tape Secondary Instrument)
Accuracy: ±2%FS
Repeatability: ±1%FS
Stability: ±1%FS/7d
Response Time: T90<60s (After full preheating)
Consumption: <20VA
Analog Output: 4~20mA/ 0~20mA (Configurable)
Probe Insertion Depth: 400mm, 600mm(standard E), 1500mm (or other sizes customized)
Communication: RS232(standard)/RS485(optional)
Instrument Ambient Temperature: -10~+50°C;
Probe Ambient Temperature: 0~+500°C
Ambient Humidity: <90%RH